AC2000 Mk4 2000kg

  • Heavy Duty Pulling Winch with Freespool
  • 2000kg Line Pull
  • 240v x 1ph / 415v x 3ph AC Winch
file_downloadBrochure file_downloadManual mailEnquire

FEATURES INCLUDE

  • Single or 3 phase options
    A choice of 240v or 415v across the range
  • Freespool clutch
    Enables easy unspooling of wire rope
  • Induction braked motor
    Provides instant, safe braking
  • Low voltage control
    Low voltage 24v in the handset – Includes Emergency stop and 3m cables pre-wired to the winch as standard
  • Motor to IP54 as Standard
    Other options available on request
  • 2 metre power lead
    Pre-wired to the winch with commercial type plug

ADDITIONAL EQUIPMENT

  • Wire rope
  • Heavy duty mounting plate and roller guide 
  • Tension roller
  • Radio remote control
  • Skid mounting frame
  • Weather proof enclosure

STANDARDS & BHW GROUP

The BS EN14492-1 for power driven winches ensures conformity to both the essential Health and Safety requirements of the UK Health and Safety Act 1994 and the EN Machinery Directive.

Conformity to these standards is the joint responsibility of the supplier, the installer and the company operating the product.

BHW Group products are fully compliant and carry a UKCA/CE mark. A Declaration of Conformity is also supplied with each winch or hoist.

Our aim at BHW Group is to ensure the correct machine is supplied to suit the application and we welcome the opportunity of discussing the proposed application and offer advice. It will help us considerably if information regarding the maximum and average loads to be lifted or pulled – and approximate frequency of use can be provided.

For hoisting applications the minimum breaking force (MBF**) of the wire rope must be 5 x the lifting capacity of the hoist. The ratio of wire rope diameter to mean drum diameter* is usually at least 15:1. This will vary according to the application, the average operating time per day and the average and maximum weights being lifted.

For pulling applications. As a general rule winches used in pulling applications rarely see their maximum rated capacity and are used intermittently for short running periods. In these applications the wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* as low as 10.1. In applications where the winch is used for longer running times and more frequently sees higher loading conditions the wire rope to MBF** should be 3:1 and the ratio of wire rope to mean drum ratio* 12:1.

For recovery vehicles the permissible standard of wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* only 10:1. This minimum standard is permitted because the running time is so short and the winch rarely sees maximum load.

Wire rope capacities the maximum amount of wire rope on the drum must leave a freeboard to the top of the drum flange of 1.5 x wire rope diameter to prevent the wire rope coming off the drum. Winches and hoists with capacities over 1000kg must be load limited.

* Mean drum diameter = the drum diameter plus the diameter of the wire rope. ** MBF = the Minimum Breaking Force of the wire rope.